QMS 2300 SENSOR RESET INSTRUCTIONS
TROUBLESHOOTING
NOTE: Only use this procedure when necessary such as if the
Developer Roller indicates a problem, contamination, lines etc.
1. Unscrew the three gold screws on
the side of the cartridge along with the
screw on the copper contact.
2. Carefully lift the contact and remove
the end cap. You should also remove
the white gears.
3. Remove the doctor blade by unscrewing
the screws. You should gently wipe in one
direction, or remove any obstacles.
4. Remove the developer roller by
turning the white endcap on the gear
side and lifting roller out.
5. Recovery blades should be gently
cleaned with a Q-tip without applying
pressure.
6. Clean the developer roller by
blowing it off or carefully wiping it.
NOTE: Do not use a vaccuum or touch
the smaller supply roller.


General Toner Refills Instructions- Index Page 1 - Index Page 2- Page 4- Page 5- Page 6- Page 7- Page 8- Page 9- Page 10- Page 11- Page 12- Page 13- Page 14- Page 15- Page 16- Page 17- Page 18- Page 19- Page 20- Page 21- Page 22- Page 23- Page 24- Page 25- Page 26- Page 27- Page 28- Page 29- Page 30- Page 31- Page 32- Page 33- Page 34- Page 35- Page 36- Page 37- Page 38- Page 39- Page 40- Page 41- Page 42- Page 43- Page 44- Page 45- Page 46- Page 47- Page 48- Page 49- Page 50- Page 51- Page 52- Page 53- Page 54- Page 55- Page 56- Page 57- Page 58- Page 59- Page 60- Page 61- Page 62- Page 63- Page 64- Page 65- Page 66- Page 67- Page 68- Page 69- Page 70- Page 71-